This is the authors' abstract. We don't add key points for this paper.
The frequency of the calcium ³P₁-¹S₀ intercombination line at 657 nm is phase-coherently measured in terms of the output of a primary cesium frequency standard using an optical frequency comb generator comprising a sub-10-fs Kerr-lens mode-locked Ti:sapphire laser and an external microstructure fiber for self-phase-modulation. The measured frequency of νCa=455 986 240 494 276 Hz agrees within its relative uncertainty of 4×10^-13 with the values previously measured with a conceptually different harmonic frequency chain and with the value recommended for the realization of the SI unit of length.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Stenger et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: