A hybrid technique using a transcatheter valve mounted on an annuloplasty ring can successfully replace a dysfunctional mechanical mitral valve in a pediatric patient.
Hybrid mitral valve replacement may offer a pediatric bailout option; leaves open durability and applicability questions.
An 11-year old boy, with complex left ventricular morphology in the setting of repaired double outlet right ventricle developed progressive mitral regurgitation leading to a repair which failed, necessitating replacement of the valve with a 21 mm St. Jude mechanical prosthesis. He represented 3 weeks later in extremis with signs of severe mitral stenosis. The valve was replaced via a hybrid technique with a 26 mm Edwards Sapien 3 valve mounted on a MEMO 3D annuloplasty ring. One year later, the valve is functioning well with no regurgitation or evidence of an inflow gradient.
No takes yet. Share an insight, caveat, or question.
Murphy et al. (2016) studied this question.