Authors
This article investigates the static characteristics of both doubly-salient brushless machines having magnets in stator, namely the flux-switching permanent magnet machine (three-phase topology) and doubly-salient permanent magnet machines (including three-phase and two-phase structures), especially taking the influence of end-effect into account. The structures and operating principles are described first, and then the end-effect in the stator permanent magnet machines is investigated by a 3-D calculation, and a leakage factor reflecting end-effect is defined to modify the 2-D predicted results. The proposed approach is validated experimentally for the prototype machines.
No takes yet. Share an insight, caveat, or question.
Hua et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: