This is the authors' abstract. We don't add key points for this paper.
We have conducted dielectric-breakdown tests on water subject to a single unipolar pulse. The peak voltages used for the tests range from 5.8 to 6.8 MV; the effective pulse widths range from 0.60 to 1.1 μs; and the effective areas tested range from 1.8×10⁵ to 3.6×10⁶ cm². The tests were conducted on water-insulated coaxial capacitors. The two electrodes of each capacitor have outer and inner radii of 99 and 56 cm, respectively. Results of the tests are consistent with predictions of the water-dielectric-breakdown relation developed in [Phys. Rev. ST Accel. Beams 9, 070401 (2006)].
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Stygar et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: