Answers are grounded in this paper and cite their sources.
A method for evaluating the sensitivity of MRI protocols to changes in an arbitrary number of tissue parameters over a broad range of parameter values is presented. This analysis is useful for choosing an optimal basis set of images for either a "survey" protocol or tissue segmentation algorithms. A survey protocol is required when searching for a lesion of unknown type or location. Segmentation requires unique signal signatures for tissues that may cover a broad range of tissue parameter values. Data acquisition is modeled as a mapping of a domain of tissue parameter values into a signal manifold in a signal strength space defined by the MRI protocol. The efficacy of the protocol is evaluated by investigating the characteristics of the signal manifold. A figure of merit which maximizes the probability of discriminating each point in the domain of tissue parameters from all others is developed.
No takes yet. Share an insight, caveat, or question.
McVeigh et al. (1990) studied this question.