In this paper, unbalanced operations of induction and synchronous machines are discussed. The current-voltage differential equations, referred to the moving reference axes α and ß, are derived directly from the general equations of armature reaction and induced voltage. Kron's tensor transformation is used to develop a reciprocal system representing the actual machine under unbalanced operations. As an illustration, the line-to-line short-circuit case of a synchronous machine is solved in detail. An approximate solution for the differential equation with variable coefficients is proposed.
No takes yet. Share an insight, caveat, or question.
H. H. Hwang (1965) studied this question.