Key result
Mechanical valve replacement shows no survival benefit over tissue valves in dialysis patients.
Why the study?
Mechanical valves are often used in renal dialysis patients due to presumed rapid degeneration of tissue valves, prompting a comparison of outcomes between mechanical and tissue valves in this population.
Does the type of prosthetic valve substitute (mechanical vs tissue) affect long term survival in renal dialysis patients?
Cohort (n=56)
Does the type of prosthetic valve substitute (mechanical vs tissue) affect long term survival in renal dialysis patients?
This study investigates whether mechanical valves offer a survival advantage over tissue valves in dialysis patients, addressing the presumption of rapid tissue valve degeneration.
Valve selection in dialysis patients remains uncertain; leaves open any survival advantage of mechanical over tissue prostheses.
Introduction: Mechanical valves are often used in renal dialysis patients due to presumed rapid degeneration of tissue valves. The purpose of this study was to compare the results of mechanical and tissue valves placed in renal dialysis patients. Materials: A computer database, phone interviews and patient charts were reviewed for followup data. Statistic analysis was performed by SPSS 13.0. Results: 56 patients underwent valve replacement between 1997 and 2006. 33 patients received 39 mechanical valves (26 aortic, 12 mitral and 1 tricuspid). 23 patients received 26 tissue valves (18 aortic, 7 mitral and 1 pulmonary). Patients in the mechanical group had a tendentially lower logistic Euroscore (16.1±17.56% vs. 23.96±19.97%; ns). Patient followup for the mechanical and tissue groups was 53.83 and 33.51 patient years respectively. 30 day mortality was 21.2% (7/33) and 21.7% (5/23) for mechanical and tissue valve groups respectively (ns, p>0.05). Overall mortality (operative and late) was 45.4% for the mechanical group (15/33) and 43.8% (10/23) for the tissue group (ns p>0.05). Structural valve degeneration requiring reoperation occured in 4.34% (1/23) of the tissue valves in the followup period. Kaplan-Meier freedom from thrombembolism (mech/bio: 1/0), haemorrhage (1/1), valve related mortality (4/4) and valve related mortality or morbidity (17/12) at 3 years demonstrated no significant difference (ns p>0.05). Conclusions: Dialysis patients had poor survival, irrespective of age; structural valve deterioration was negligible. There was no long term superiority of mechanical prostheses over biological prostheses in terms of freedom from valve related complications. Bioprostheses should be considered for treatment of valvular disease in end stage renal disease patients.
No takes yet. Share an insight, caveat, or question.
Easo et al. (2007) conducted a cohort in Renal dialysis (end-stage renal disease) requiring cardiac valve replacement (n=56). Mechanical prosthetic valve replacement vs. Tissue (biological) prosthetic valve replacement was evaluated on Overall mortality (operative and late) (p=>0.05). Mechanical valve replacement showed similar overall mortality to tissue valves in dialysis patients (45.4% vs 43.8%, p>0.05), with no superiority in 3-year valve-related complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: