The depth distribution of deuterium in metal targets has been measured by sputtering the metal surface with a 60 keV Bi beam and monitoring the partial pressure of deuterium released into the target chamber with an MS 10 mass spectrometer. No significant differences were found for the distributions from D+, D 2 +, and D 3 + bombardments with 20 and 30 keV energy per incident atom.The sputtering coefficient, measured by the loss in weight of a target, was used to calculate ranges for the energy interval 5–80 keV. These are compared with previous experimental and theoretical values.
No takes yet. Share an insight, caveat, or question.
Freeman et al. (1968) studied this question.