Why the study?
No ideal approach is established to evaluate heart grafts, with assessment relying mostly on qualitative surgical interpretation of anatomy, color, and manual palpation.
Does quantitative assessment of Shear Wave Velocity (SWV) using ultrasound correlate with cardiac graft viability in a porcine model?
Does quantitative assessment of Shear Wave Velocity (SWV) using ultrasound correlate with cardiac graft viability in a porcine model?
Quantitative assessment of myocardial stiffness using ultrasound shear wave velocity correlates with cardiac function and may serve as a biomarker for graft viability in heart transplantation.
SWV may enable quantitative graft viability assessment in transplantation; leaves open human validation and clinical adoption.
Background Heart transplantation is the definitive treatment for many cardiovascular diseases. However, no ideal approach is established to evaluate heart grafts and it mostly relies on qualitative interpretation of surgeon based on the organ aspect including anatomy, color and manual palpation. In this study we propose to assess quantitatively the Shear Wave Velocity (SWV) using ultrasound as a biomarker of cardiac viability on a porcine model. Methods The SWV was assessed quantitatively using a clinical ultrasound elastography device (Aixplorer, Supersonics Imagine, France) linked to a robotic motorized arm (UR3, Universal Robots, Denmark) and the elastic anisotropy was obtained using a custom ultrasound research system. SWV was evaluated as function of time in two porcine heart model during 20h at controlled temperature (4°C). One control group ( N = 8) with the heart removed and arrested by cold cardioplegia and immerged in a preservation solution. One ischemic group ( N = 6) with the organ harvested after 30 min of in situ warm ischemia, to mimic a donation after cardiac death. Hearts graft were revived at two preservation times, at 4 h ( N = 11) and 20 h ( N = 10) and the parameters of the cardiac function evaluated. Findings On control hearts, SWV remained unchanged during the 4h of preservation. SWV increased significantly between 4 and 20h. For the ischemic group, SWV was found higher after 4h (3.04 +/- 0.69 vs 1.69+/-0.19 m/s, p = 0.007) and 20h (4.77+/-1.22 m/s vs 3.40+/-0.75 m/s, p = 0.034) of preservation with significant differences. A good correlation between SWV and cardiac function index was found (r 2 =0.88) and manual palpation score (r 2 =0.81). Interpretation Myocardial stiffness increase was quantified as a function of preservation time and harvesting conditions. The correlation between SWV and cardiac function index suggests that SWV could be used as a marker of graft viability. This technique may be transposed to clinical transplantation for assessing the graft viability during transplantation process. Funding FRM PME20170637799, Agence Biomédecine AOR Greffe 2017, ANR-18-CE18-0015.
No takes yet. Share an insight, caveat, or question.
Pedreira et al. (2022) studied this question.