Answers are grounded in this paper and cite their sources.
The response of osteoblast-like cells to different implant surface textures was evaluated in this laboratory study. Rough disks of commercially pure titanium were cut from bar stock and prepared as irregular or regular surface morphology at the microscopic level. The irregular samples were polished with 600 grit sandpaper and sandblasted with aluminum oxide particles or etched with hydrofluoric or nitric acid. The regular samples were polished with 60 or 120 grit sandpaper without any microabrasion or etching. Control samples were polished with 600 grit sandpaper only. Each sample was exposed to osteoblast-like cells which were obtained from rat calvarial explants. The number of cells which attached to the samples were calculated. The highest degree of cell attachment was obtained on the samples with the sandblasted surface. The authors hypothesized that the sandblasted surface may provide more available surface area for attachment of cells and extracellular matrix, and suggested further study.
No takes yet. Share an insight, caveat, or question.
Kt et al. (1993) studied this question.