Why the study?
Does acquiring cine sequences after gadolinium injection affect the qualitative and quantitative assessment of LV function compared to before injection in patients undergoing 3T cardiac MRI?
Does acquiring cine sequences after gadolinium injection affect the qualitative and quantitative assessment of LV function compared to before injection in patients undergoing 3T cardiac MRI?
In 3T cardiac MRI, LV function can be reliably assessed using cine sequences acquired after gadolinium injection, potentially improving scanning time efficiency.
Answers are grounded in this paper and cite their sources.
Post-contrast cine sequences allow reliable LV assessment at 3T despite lower quality; leaves open whether routine adoption shortens exams in larger trials.
OBJECTIVES: To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. METHODS: 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm. RESULTS: No difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after > cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef>0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef>0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after > cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef>0) = 15%). CONCLUSIONS: In 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality.
No takes yet. Share an insight, caveat, or question.
Caspar et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: