Key result
EECP increases diastolic intracoronary pressure by ~93% while reducing systolic pressure.
Answers are grounded in this paper and cite their sources.
BACKGROUND: Enhanced external counterpulsation (EECP) is a noninvasive, pneumatic technique that provides beneficial effects for patients with chronic, symptomatic angina pectoris. However, the physiological effects of EECP have not been studied directly. We examined intracoronary and left ventricular hemodynamics in the cardiac catheterization laboratory during EECP. METHODS AND RESULTS: Ten patients referred for diagnostic evaluation underwent left heart catheterization and coronary angiography from the radial artery. At baseline and then during EECP, central aortic pressure, intracoronary pressure, and intracoronary Doppler flow velocity were measured using a coronary catheter, a sensor-tipped high-fidelity pressure guidewire, and a Doppler flow guidewire, respectively. Similar to changes in aortic pressure, EECP resulted in a dramatic increase in diastolic (71+/-10 mm Hg at baseline to 137+/-21 mm Hg during EECP; +93%; P<0.0001) and mean intracoronary pressures (88+/-9 to 102+/-16 mm Hg; +16%; P=0.006) with a decrease in systolic pressure (116+/-20 to 99+/-26 mm Hg; -15%; P=0.002). The intracoronary Doppler measure of average peak velocity increased from 11+/-5 cm/s at baseline to 23+/-5 cm/s during EECP (+109%; P=0.001). The TIMI frame count, a quantitative angiographic measure of coronary flow, showed a 28% increase in coronary flow during EECP compared with baseline (P=0.001). CONCLUSIONS: EECP unequivocally and significantly increases diastolic and mean pressures and reduces systolic pressure in the central aorta and the coronary artery. Coronary artery flow, determined by both Doppler and angiographic techniques, is increased during EECP. The combined effects of systolic unloading and increased coronary perfusion pressure provide evidence that EECP may serve as a potential mechanical assist device.
No takes yet. Share an insight, caveat, or question.
Michaels et al. (2002) studied Chronic, symptomatic angina pectoris / patients referred for diagnostic cardiac catheterization (n=10). Enhanced external counterpulsation (EECP) vs. Baseline (pre-EECP) was evaluated on Diastolic intracoronary pressure (mm Hg) (+93%, p=<0.0001). Enhanced external counterpulsation increased diastolic intracoronary pressure by 93% and Doppler peak flow velocity by 109% while reducing systolic pressure by 15%.
Synapse has enriched 10 related papers. Consider them for comparative context: