Is the reproducibility of atrial signal-averaged electrocardiogram comparable to conventional ventricular signal-averaged electrocardiogram in healthy subjects?
Is the reproducibility of atrial signal-averaged electrocardiogram comparable to conventional ventricular signal-averaged electrocardiogram in healthy subjects?
Atrial SAECG demonstrates satisfactory reproducibility for P-wave duration but poor reproducibility for voltage parameters, which should be considered in clinical applications.
P-wave duration parameters show acceptable reproducibility in atrial SAECG; leaves open reliability of RMS voltages before clinical or research adoption.
Although atrial signal-averaged electrocardiogram (SAECG) has been proposed for noninvasive identification of patients with atrial tachyarrhythmias, the substantial variability of the measurement limits the clinical value. The aim of the study was to assess the short- to long-term reproducibility of atrial SAECG and to compare it to that of the conventional ventricular SAECG in 51 healthy volunteers (30 men; age 32 +/- 8 years). In each subject, SAECG recordings were obtained using MAC-VU electrocardiograph and HiRES and PHiRES software (Marquette Medical Systems) and repeated after 5 minutes, 1 day, 1 week, and 1 month. Automatically detected onset and offset of the filtered QRS complex and P wave were subsequently corrected by two independent observers, and the averaged values were used for the analysis. Conventional ventricular SAECG parameters: filtered QRS duration (QRStot), low amplitude signal duration, and root mean square voltage (RMS) of the terminal 40 ms of QRS, and 5 atrial parameters: filtered P wave duration (Ptot), RMS of the terminal 40, 30, 20 ms, and of the entire P wave were obtained. Relative errors of different pairs of measures were used to assess the intrasubject reproducibility. QRStot and Ptot were the most reproducible parameters. The relative errors after 5 minutes, 1 day, 1 week, and 1 month were 0.8% to 2.4% for QRStot, and 1.3% to 4.2% for Ptot. For RMS voltages, the relative errors exceeded 15% in short-term and 20% in long-term recordings. Although Ptot was statistically less reproducible than QRStot, the reproducibility of the former was good and comparable to that of the QRStot. The reproducibility of the voltage parameters was significantly poorer than that of the duration parameters. The study showed a satisfactory short- and long-term reproducibility of Ptot in the atrial SAECG in healthy subjects. However, low reproducibility of the voltage parameters should be considered in clinical applications.
No takes yet. Share an insight, caveat, or question.
SAVELIEVA et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: