Why the study?
Does on-screen measurement of P wave duration provide lower measurement errors compared to on-paper or on-board methods in normal subjects and patients with atrial fibrillation?
Does on-screen measurement of P wave duration provide lower measurement errors compared to on-paper or on-board methods in normal subjects and patients with atrial fibrillation?
On-screen manual measurement of P wave duration provides more stable results with lower intraobserver and interobserver errors compared to paper or digitizing board methods.
On-screen P-wave measurement may minimize errors in practice; leaves open need for outcome validation in prospective studies.
To determine whether different methods for the manual measurement of P wave duration are mutually consistent, we evaluated the intraobserver and interobserver errors of P wave measurements obtained in three different ways: (1) by cursor on a high resolution computer screen (on screen), (2) by calipers and a magnifying glass (on paper), and (3) by a high resolution digitizing board (on board). The agreement between the methods was assessed in 30 normal subjects and 30 patients with a history of atrial fibrillation. The maximum P wave duration (P maximum), the minimum P wave duration (P minimum), mean P wave duration (P mean), P wave dispersion (P dispersion = P maximum - P minimum), and the standard deviation of the P wave duration in all measured leads (P SD) were calculated from a 12-lead electrocardiogram in each subject. Only P maximum, P mean, and P dispersion were significantly higher in patients than in controls with all three methods. Intraobserver and interobserver relative errors were significantly different among the three methods; the lowest errors were associated with the on-screen measurement. The agreement between the three different methods was acceptable for P maximum, P mean, and P SD and rather poor for P minimum and P dispersion in both groups. The differences of the measurement by different methods did not consistently differ between the two groups. Hence, the on-screen measurements are consistent with other manual methods and provide more stable results. Manual measurement of ECG patterns should be preferably performed with digital ECG recordings displayed on a high resolution computer screen.
No takes yet. Share an insight, caveat, or question.
Dilaveris et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: