A novel computational approach using Navier-Stokes equations allows for the derivation of flow pressure fields from magnetic resonance velocity mapping data.
Answers are grounded in this paper and cite their sources.
May advance noninvasive MR pressure mapping; leaves open in vivo validation before clinical use.
Magnetic resonance phase velocity mapping has unrivalled capacities for acquiring in vivo multi-directional blood flow information. In this study, the authors set out to derive both spatial and temporal components of acceleration, and hence differences of pressure in a flow field using cine magnetic resonance velocity data. An efficient numerical algorithm based on the Navier-Stokes equations for incompressible Newtonian fluid was used. The computational approach was validated with in vitro flow phantoms. This work aims to contribute to a better understanding of cardiovascular dynamics and to serve as a basis for investigating pulsatile pressure/flow relationships associated with normal and impaired cardiovascular function.
No takes yet. Share an insight, caveat, or question.
Yang et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: