Answers are grounded in this paper and cite their sources.
Performance characteristics of the jet pump when handling viscous oil have been established. Theoretical relations describing the jet pump are developed in this paper in terms of dimensionless ratios and friction coefficients. In addition, an energy analysis is made which separates friction losses and unavoidable mixing losses. In an experimental program eight jet pumps, with nozzle-to-throat area ratios of 0.1 to 0.6, were operated over a range of jet Reynolds numbers from 700 to 30,000. Mineral and synthetic lubricating oils used covered a 5 to 100-centistoke viscosity range of the jet fluid. The results of these theoretical and experimental studies permit application of the jet pump to lubrication systems. For design use the experimental data are reduced to friction coefficients and correlated versus jet and throat Reynolds numbers. To facilitate rapid estimates of viscosity effects, simplified empirical relations are also included. It is concluded from this study that the jet pump is indeed suitable for use with viscous fluids.
No takes yet. Share an insight, caveat, or question.
Richard Cunningham (1957) studied this question.