Answers are grounded in this paper and cite their sources.
A two-stage multi-objective optimization framework based on NSGA-II is proposed for the high-energy beam transport (HEBT) line of an accelerator-based boron neutron capture therapy (AB-BNCT) facility. In the first stage, quadrupole magnets are optimized to achieve high transmission efficiency and a suitable beam size. In the second stage, the quadrupole settings are fixed and octupole magnets are optimized to improve beam uniformity. An adaptive penalty function is used to constrain the beam size and shape. The optimized beam yields a transmission efficiency of 99.93% and produces a uniform 120 mm × 120 mm square spot on the target. Thermal analysis shows that the maximum temperature of the lithium target reaches 120 °C, which is well below its melting point. Error analysis indicates that without correction, beam uniformity may degrade to unacceptable levels, causing local overheating. The addition of corrector magnets restores uniformity above the critical threshold in most error scenarios, thereby ensuring robust thermal stability.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.