Sir, Electrosurgical instruments are one of the useful and most used instruments within the surgeon’s armamentarium, yet their utilization carries inherent risks due to the generation of electrical current and heat. These complications, often underreported, can lead to morbidity and associated medicolegal and economic consequences. Wound healing complications, infections, and prolonged treatment can result in physical, financial, and psychological impacts on patients and their families. We present a case involving a burn injury resulting from the use of monopolar electrosurgical equipment. A 38-year-old female weighing 68 kg underwent a total abdominal hysterectomy for fibroid uterus under regional anesthesia. After administering spinal anesthesia, the patient was positioned supine, and the electrocautery pad was positioned under the buttock. The surgery proceeded without complications and was completed within 2 h. Following the procedure, the patient was transferred to the postoperative recovery ward. On the 2nd postoperative day, the patient reported a burning sensation in her left buttock. Upon examination, a burn injury was identified precisely at the location where the cautery pad had been placed during the surgical procedure which was treated with local application of antiseptic cream [Figure 1]. The patient recovered well from surgery and was discharged 7 days after the procedure.Figure 1: Burn injury on left buttock of patient due to grounding pad of electrosurgical device usage during surgeryIntraoperative electrocautery burns are categorized into four types, including direct contact burns, burns at the grounding electrode, burns resulting from electrode-heating of pooled solutions, and burns occurring outside the operative field due to circuits generated between the active electrode and an alternate grounding source.[1] Traditional monopolar electrosurgery involves the use of radiofrequency current conducted through a circuit, consisting of an electrosurgical unit, insulated cables, an active electrode, the patient, and a grounding pad. The grounding pad, applied away from the surgical site, is crucial in safely returning the electrical current to the generator, dispersing it over a wide area to minimize tissue heating.[2] High current, especially with long activation times, conductive solutions such as saline, and poor contact quality between the pad and the patient can result in patient burns.[2] Conductive solutions further complicate the process, dispersing current away from the intended site, requiring higher currents, and elevating the risk of burns.[3] Factors contributing to poor contact include hair interference, moisturizers, bony prominences, fluid invasion, scar tissue, or areas with little soft-tissue mass or obesity. The potential causes of the grounding pad burn in our case include incorrect application of the pad or desiccation of the grounding pad gel resulting in a diminished contact area. Newer electrosurgical generators incorporate a monitoring circuit, which continuously monitors the integrity of the grounding plate. Loss >25% integrity of the grounding plate will automatically shut off power to the device and give an audio and visual alarm until the plate is reattached. Use of fire-retardant surgical drapes and installing over-current protection devices on the electrical equipment is recommended. Innovations such as split grounding pads and newer adhesive materials aim to enhance safety.[4] Recommendations to minimize risks involve recognizing the capabilities of electrocautery devices, ensuring proper grounding pad application, educating hospital personnel, and allowing sufficient time off between activations to cool the tissue. Various factors, such as incorrect pad application or desiccation of the grounding pad gel, can contribute to grounding pad burns. Visual inspection, correct placement, and consideration of patient characteristics are essential.[5] Health-care personnel need to recognize the risks associated with high-current, long-activation time procedures, and conductive fluids during electrosurgical procedures. Suggestions include visual inspection, appropriate pad placement, controlled energy bursts, and the use of multiple grounding pads in high-risk cases.[4,5] Through this case, we emphasize the understanding of the mechanism of electrosurgery burns and the importance of taking necessary steps to minimize the risk of grounding pad burns to patients. Adhering to recommended settings for traditional electrocautery and remaining vigilant during electrosurgical procedures contribute to overall patient safety. Declaration of patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given her consent for her images and other clinical information to be reported in the journal. The patient understands that her name and initials will not be published and due efforts will be made to conceal her identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Sharmila et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: