Answers are grounded in this paper and cite their sources.
After the intra-tracheal injection in the conscious rat of 133BaSO4 particles suspended in 2.5 μI isotonic mannitol, only approximately 80% were rapidly removed from the distal trachea by mucociliary clearance. Some 20% were cleared with a mean half-time of 16 h, and approximately 1% remained in the tracheal tissue for at least 30 d. Such retention could be a basis for effects of inhaled toxic particles on the large airways. Mucus was collected from the trachea of the conscious rat and shown to exhibit shear-thinning. When BaSO4 particles suspended in the mucus were injected into another rat, clearance kinetics over 2 d were similar to those for particles suspended in mannitol.
No takes yet. Share an insight, caveat, or question.
Patrick et al. (1977) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: