Answers are grounded in this paper and cite their sources.
This paper presents the analysis and optimization procedure of a two-stage bidirectional AC/DC power supply. The exemplary power supply consists of a silicon carbide based active front end and a dual active bridge DC/DC converter. It is designed to supply 600 V DC applications from universal low voltage AC grids with a power up to 6 kW. The paper includes the topology and design considerations, as well as an in-depth loss distribution analysis based on a validated loss model. The loss model is then utilized for an operation space optimization. A special focus is drawn to the loss model and the optimization: It is based on analytical equations optimized for a low calculation effort. This enables quick modeling of a large operation space. Those results can both be used to validate design considerations as well as to optimize operating parameters. The presented dynamic operating parameter optimization enables a loss reduction at full load by 14% and at half load by even 48%. By means of the optimization the operating area can be expanded, losses decreased, and thermal stress reduced.
No takes yet. Share an insight, caveat, or question.
Fräger et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: