The Lang x-ray diffraction technique provides a simple non-destructive method for measuring flexure in single-crystal silicon wafers at different stages of integrated circuit fabrication. A molybdenum target provides Kα1 and Kα2 x-radiation which is diffracted from the set of {110} normal to the surface parallel {111}. The widths of the diffracting regions and their separation are simply related to the flexure, which may be expressed as a radius of curvature (p). This method is limited to wafers which do not diffract from the entire region irradiated, i.e. p <1590 in. for a 1 in. diameter wafer. Results indicate a change in the radius of curvature from > 1590 in. for a substrate to 203 in. after several processing stages. Non-uniformity in individual wafers is much greater after the material has been through several processing stages.
No takes yet. Share an insight, caveat, or question.
E. M. Juleff (1965) studied this question.