This is the authors' abstract. We don't add key points for this paper.
The article presents some results obtained during the investigation performed by the Structural Diagnostic laboratory of the “Centro di Ricerca e Sperimentazione Stradale di Cesano” on the “Passignano” viaduct located on the Bettolle-Perugia motorway junction managed by Anas S.p.A. It was designed by Prof. Eng. Giorgio Croci in the early 1980s. The infrastructure is characterized by girders supported on two piers with two cantilevered ends. These two ends are characterized by a 45° angle section forming an inclined joint connected by No. 30 Dywidag bars. The on-site investigation consisted of the axial stress evaluation of the joint bars under dead load using two different techniques, a static load test on span No. 7 joint and, eventually test executed during exceptional 150-ton vehicle transiting on the deck.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Santori et al. (2024) studied this question.