Key result
Brief multimodal training boosts correct blood pressure self-monitoring in pregnant women from 12% to ~97%.
Why the study?
Patient-performed blood pressure monitoring is rarely done in low- and middle-income countries, and its efficacy requires patients to correctly operate monitors and obtain accurate measurements.
Does a brief multimodal training enable pregnant women in urban Ghana to accurately and correctly perform self-blood pressure monitoring using an automatic monitor compared with pre-training baseline and clinician-performed measurements?
Cross-Sectional (n=176)
No
Does a brief multimodal training enable pregnant women in urban Ghana to accurately and correctly perform self-blood pressure monitoring using an automatic monitor compared with pre-training baseline and clinician-performed measurements?
A brief 10-minute multimodal training enables pregnant women in an urban low- and middle-income setting to accurately and correctly perform self-blood pressure monitoring across diverse education levels.
Answers are grounded in this paper and cite their sources.
Brief training enables accurate self-BP monitoring by pregnant women in urban Ghana; extends feasibility data to LMIC settings but leaves open outcome trials.
Patient-performed blood pressure monitoring in pregnancy is rarely performed in low- and middle-income country settings, including Ghana. The clinical efficacy of home blood pressure monitoring relies on a pregnant patient being able to independently execute the correct steps to position and use a blood pressure monitor, and to achieve accurate blood pressure measurements. This study aimed to: (1) assess if pregnant women can correctly use an automatic blood pressure monitor to check their own blood pressure before and after a brief training; and (2) determine if blood pressure values measured by pregnant women using an automatic monitor are similar to values measured by a healthcare provider using a standard clinic monitor. This was a cross-sectional study conducted at the Korle Bu Teaching Hospital, a tertiary hospital in Accra, Ghana. Participants were adult pregnant women presenting for their first prenatal care visit. Data collection was conducted by two Ghanaian physicians. Information on demographics, obstetric history, and past medical history was collected. A brief training was provided on correct use of the blood pressure monitor, including a verbal script, annotated photographs, and hands-on demonstration. Pre- and post-training assessments using a 9-item checklist of correct preparation, position, and use of an automatic blood pressure monitor were conducted. Following a modified British Hypertension Society protocol, a series of four blood pressure measurements were taken, alternating between provider-performed using a clinic monitor and patient-performed using an automatic monitor intended for individual use and validated in pregnancy. Among 176 participants, the mean age was 31.5 years (± 5.6) and 73.9% (130/176) were multiparous. Regarding socioeconomic characteristics, 72.7% (128/176) were married, 97.2% (171/176) had public insurance, and 49.7% (87/176) had completed ≤9 years of formal education. Regarding clinical blood pressure issues, 10.9% (19/176) had a history of a hypertensive disorder in a prior pregnancy and 3.4% (6/176) had chronic hypertension. Prior to receiving any training, 12.1% (21/176) of participants performed all nine steps correctly to prepare, position, and use the automatic blood pressure monitor. Comparing pre-training to post-training ability, statistically significant increases were seen in correct performance of each individual step, as well as mean number of steps performed correctly (6.1 ± 1.8 vs 9.0 ± 0.2, p<0.001) and proportion performing all nine steps correctly (12.1% vs 96.6%, p<0.001). The mean difference between doctor-performed and patient-performed blood pressure measurements were 5.6 ± 4.8 mmHg for systolic values and 3.4 ± 3.08 mmHg for diastolic values, with most differences within 5 mmHg for both systolic (58.0%, 102/176) and diastolic (80.1%, 141/176) values. After a brief training, pregnant women in Ghana demonstrate that they are able to use an automatic blood pressure monitor to check their own blood pressure correctly and accurately.
No takes yet. Share an insight, caveat, or question.
Lawrence et al. (2023) conducted a cross-sectional in Pregnancy (blood pressure monitoring for hypertensive disorders of pregnancy) (n=176). Brief multimodal training (≤10 minutes) and patient-performed automatic blood pressure monitoring vs. Pre-training baseline ability and healthcare provider-performed blood pressure measurement using a standard clinic automatic monitor was evaluated on Proportion of participants performing all 9 steps correctly to prepare, position, and use an automatic blood pressure monitor (p=<0.001). Brief multimodal training increased the proportion of pregnant women correctly performing all 9 blood pressure monitoring steps from 12.1% to 96.6%, with 58.0% of systolic readings within 5 mmHg of clinician measurements.
Synapse has enriched 10 related papers. Consider them for comparative context: