Why the study?
Does graded hemorrhage and intravascular volume replacement affect systolic pressure variation and delta down in mechanically ventilated and spontaneously breathing humans?
Does graded hemorrhage and intravascular volume replacement affect systolic pressure variation and delta down in mechanically ventilated and spontaneously breathing humans?
Systolic pressure variation and delta down are reliable indicators of intravascular volume depletion during mechanical ventilation, but are unreliable during spontaneous ventilation.
Answers are grounded in this paper and cite their sources.
May support SPV and delta down for volume assessment during mechanical ventilation; leaves open reliability in spontaneous breathing.
In dogs and humans, the magnitude of the variation in systolic pressure (SPV) over the respiratory cycle during mechanical ventilation appears to be inversely related to intravascular volume. Also reported to correlate with changes in volume status is delta down, the difference between systolic pressure at end-expiration and the lowest value during the respiratory cycle. These variables were examined during graded hemorrhage in eight anesthetized, mechanically ventilated subjects, and seven awake, spontaneously breathing subjects. SPV and delta down were measured in sequence at baseline, after 500 mL blood removal, after 1000 mL (total) blood removal, after 500 mL hetastarch replacement, after 1000 mL (total) hetastarch replacement, and after 500 mL normal saline (NS). Repeated-measures analysis of variance was used to test the significance of the change in SPV and delta down among the interventions. During mechanical ventilation, each 500-mL hemorrhage significantly increased SPV and delta down, and each 500-mL hetastarch infusion significantly decreased SPV and delta down. After hetastarch, both SPV and delta down were smaller than at baseline and may explain why the infusion of NS caused nonsignificant reductions in SPV and delta down. A SPV of 5 mm Hg or less, or a delta down of 2 mm Hg or less appeared to indicate minimal intravascular volume depletion. During spontaneous ventilation, delta down could not be determined accurately in several subjects, and SPV did not change in the appropriate direction in all cases of hemorrhage and volume infusion.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Rooke et al. (1995) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: