Key result
An amperometric immunosensing strategy detected periostin with a limit of detection of 0.14 ng/mL, successfully differentiating between healthy controls and colorectal cancer patients in 60 minutes.
Why the study?
Periostin is envisioned as a potential stromal prognostic biomarker in colorectal cancer to facilitate pertinent treatments, but tools to determine it are needed.
The developed amperometric immunosensor provides a rapid and sensitive method for detecting periostin, a potential prognostic biomarker in colorectal cancer.
Answers are grounded in this paper and cite their sources.
May enable rapid periostin detection in colorectal cancer; leaves open validation in larger cohorts before clinical adoption.
Tumor‐associated stroma biomarkers are emerging as key signaling molecules of metastasis in colorectal cancer (CRC). In this sense, periostin (POSTN), a protein of the extracellular matrix from the stromal compartment, is envisioned as a potential stromal prognostic biomarker, which facilitates the application of pertinent treatments. In this work, we report an easy‐to‐handle amperometric sandwich‐based immunosensing strategy for the determination of POSTN involving commercial magnetic microparticles (MBs), disposable carbon electrodes, and the horseradish peroxidase (HRP)/H 2 O 2 /hydroquinone (HQ) electrochemical system. The method allowed a dynamic linear range between 0.47 and 25 ng mL −1 and a limit of detection, LOD, of 0.14 ng mL −1 compatible with clinical demands. The method was applied to the analysis of POSTN in a variety of cancer‐related real bio‐scenarios including cell extracts and secretomes from CRC cells, and plasma from CRC patients at different stages. The potentials of this firstly developed MBs‐assisted immunoplatform are justified by distinguishing between metastatic abilities of cultured CRC cells through the analysis of their extracts and secretomes, and by differentiating between healthy controls and CRC patients in just 60 min. Therefore, the developed immunoplatform can be envisaged as a novel and profitable tool for exploring the most uncharacterized but prospective tumor areas.
No takes yet. Share an insight, caveat, or question.
Blázquez‐García et al. (2023) studied Colorectal cancer. Amperometric sandwich-based immunosensing strategy vs. Healthy controls was evaluated on Limit of detection and dynamic linear range for periostin (POSTN). An amperometric immunosensing strategy detected periostin with a limit of detection of 0.14 ng/mL, successfully differentiating between healthy controls and colorectal cancer patients in 60 minutes.
Synapse has enriched 10 related papers. Consider them for comparative context: