Key result
Adding resting DE-CTP to CCTA improves diagnostic accuracy for flow-limiting stenoses to AUC ~0.96.
Observational (n=54)
Answers are grounded in this paper and cite their sources.
Demonstrates that adding resting dual-energy CT perfusion to coronary angiography improves detection of flow-limiting stenoses, indicating reduced diagnostic errors.
Background Rest/stress myocardial CT perfusion (CTP) has high diagnostic value for coronary artery disease (CAD), but the additional value of resting CTP especially dual-energy CTP (DE-CTP) beyond coronary CT angiography (CCTA) in chest pain triage remains unclear. We aimed to evaluate the diagnostic accuracy of resting myocardial DE-CTP, and additional value in detecting CAD beyond CCTA (obstructive stenosis: ≥ 50%) in patients suspected of CAD. Methods In this prespecified subanalysis of 54 patients, we included patients suspected of CAD referred to invasive coronary angiography (ICA). Diagnostic accuracy of resting myocardial DE-CTP in detecting myocardial perfusion defects was assessed using resting 13 N-ammonia positron emission tomography (PET) as the gold standard. Diagnostic accuracy of cardiac dual-energy CT in detecting flow-limiting stenoses (justifying revascularization) by CCTA combined with resting myocardial DE-CTP, using ICA plus resting 13 N-ammonia PET as the gold standard. The CCTA and DE-CTP datasets derived from a single-phase scan performed with dual-energy mode. Results For detecting myocardial perfusion defects, DE-CTP demonstrated high diagnostic accuracy with a sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of 95.52%, 85.93%, and 0.907 on a per-segment basis. For detecting flow-limiting stenoses by CCTA alone, sensitivity, specificity, and AUC were 100%, 56.47%, and 0.777 respectively on a per-vessel basis. For detecting flow-limiting stenoses by CCTA combined with resting myocardial DE-CTP, sensitivity, specificity, and AUC were 96.10%, 95.29% and 0.956 respectively on a per-vessel basis. Additionally, CCTA combined with resting myocardial DE-CTP detected five patients (9%) with no obstructive stenosis but with myocardial perfusion defects confirmed by ICA plus 13 N-ammonia PET. Conclusions Resting cardiac DE-CTP demonstrates a high diagnostic accuracy in detecting myocardial perfusion defects and provides an additional clinical value by reducing rates of false-positive and false-negative patients beyond CCTA in patients suspected of CAD.
No takes yet. Share an insight, caveat, or question.
Li et al. (2022) conducted an observational in Suspected coronary artery disease (n=54). Coronary CT angiography (CCTA) combined with resting myocardial dual-energy CT perfusion (DE-CTP) vs. CCTA alone (with invasive coronary angiography plus resting 13N-ammonia PET as gold standard) was evaluated on Diagnostic accuracy for detecting flow-limiting stenoses on a per-vessel basis (AUC) (AUC 0.956 vs 0.777). Adding resting myocardial DE-CTP to CCTA improved per-vessel diagnostic accuracy for flow-limiting coronary stenoses compared to CCTA alone.
Synapse has enriched 10 related papers. Consider them for comparative context: