Key result
CT-MPI with regadenoson demonstrated an accuracy of 79.1% (95% CI 57.9-92.87) for detecting myocardial ischemia compared to SPECT, with similar radiation exposure (4.4 vs 5.6 mSv, P=0.401).
Why the study?
The study evaluated regadenoson-induced dynamic CT myocardial perfusion imaging compared with SPECT for ischemia detection, safety, radiation exposure, and patient experience.
Does CT-MPI with regadenoson provide comparable accuracy, safety, and radiation exposure to SPECT for detecting myocardial ischemia in patients undergoing clinically indicated SPECT?
Cross-Sectional (n=24)
Does CT-MPI with regadenoson provide comparable accuracy, safety, and radiation exposure to SPECT for detecting myocardial ischemia in patients undergoing clinically indicated SPECT?
Effect estimate: Accuracy 79.1% (95% CI 57.9-92.87)
CT-MPI with regadenoson is a safe and well-tolerated alternative to SPECT, offering high specificity and comparable radiation exposure while providing both anatomic and perfusion assessment.
Supports CT-MPI feasibility with regadenoson; leaves open diagnostic accuracy and clinical utility pending larger studies.
OBJECTIVES: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging. MATERIALS AND METHODS: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial. All patients underwent coronary CT angiography and CT-MPI with hyperemia induced by the intravenous administration of regadenoson (0.4 mg/5 mL). Patient experience and findings on CT-MPI images were compared to SPECT imaging. RESULTS: Patient experience and safety were similar between CT-MPI and SPECT procedures and no serious adverse events due to the administration of regadenoson occurred. SPECT resulted in a higher number of mild adverse events than CT-MPI. Patient radiation exposure was similar during the combined coronary computed tomography angiography and CT-MPI (4.4 [2.7] mSv) and SPECT imaging (5.6 [1.7] mSv) (P-value 0.401) procedures. Using SPECT as the reference standard, CT-MPI analysis showed a sensitivity of 58.3% (95% confidence interval [CI]: 27.7-84.8), a specificity of 100% (95% CI: 73.5-100), and an accuracy of 79.1% (95% CI: 57.9-92.87). Low apparent sensitivity occurred when the SPECT defects were small and highly suspicious for artifacts. CONCLUSIONS: This study demonstrated that CT-MPI is safe, well tolerated, and can be performed with comparable radiation exposure to SPECT. CT-MPI has the benefit of providing both complete anatomic coronary evaluation and assessment of myocardial perfusion.
No takes yet. Share an insight, caveat, or question.
Assen et al. (2020) conducted a cross-sectional in Suspected myocardial ischemia (n=24). CT-MPI with regadenoson vs. SPECT imaging was evaluated on Accuracy for detection of myocardial ischemia using SPECT as the reference standard (Accuracy 79.1%, 95% CI 57.9-92.87). CT-MPI with regadenoson demonstrated an accuracy of 79.1% (95% CI 57.9-92.87) for detecting myocardial ischemia compared to SPECT, with similar radiation exposure (4.4 vs 5.6 mSv, P=0.401).