Answers are grounded in this paper and cite their sources.
Plural long short-term memory (pLSTM) with sparse model (SM) has been implemented in a developed multiple current-voltage (MCV) system (called pLSTM-SM-MCV) for the a estimation in upward vertical gas-liquid flow. The new MCV system injects constant current to measure the voltage νnk at multiple electrode pairs k at measurement time n with lower noise than the conventional multiple voltage-current (MVC) system. The measured voltage vector Vn is processed to the extracted voltage vector V~n by SM under the assumption in Vn. The V~n is trained for the flow regime identification by the 1st LSTM and the a estimation by the 2nd LSTM in pLSTM-SM-MCV. Experiments were conducted in a vertical gas-liquid experimental setup under the conditions of liquid single-phase flow, bubbly flow, and slug flow. As a result, the V~n was successfully extracted by determining the regularization parameter value λ in the sparse model as λ = 0.01 and λ = 0.042 in bubbly and slug flows, respectively. Under the λ, pLSTM-SM-MCV identifies the flow regime with zero percentage error and estimates the void fraction with a total mean of mean relative error 〈ε〉 = 0.0275 which is reduced by 42% compared to the former pLSTM without SM (pLSTM-MCV) and by 51% compared to the former pLSTM implemented in conventional MVC system (pLSTM-MVC).
No takes yet. Share an insight, caveat, or question.
Tanaka et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: