A low NOx combustor for kerosene-fueled micro gas turbine based on a new concept was proposed. The combustor consisted of primary and secondary combustion zones, and they were connected by a throat. A swirler was set between the primary and secondary combustion zones. In order to enhance recirculation of burned gas in the primary combustion zone, combustion air was introduced through the swirler and forced to flow upward to the combustor bottom. In this study, fundamental combustion characteristics such as lean combustion limit, exhaust gas composition and combustion gas temperature were measured using three fuel atomizers which rated flow rates were 3.0 gallon/h, 4.5 gallon/h and 6.0 gallon/h respectively. It was shown that the combustion stability and emission characteristics in the case of 3.0 gallon/h nozzle were superior to those in other cases. Further, gas velocity in the primary combustion zone was measured by Leaser Doppler Anemometer (LDA) and behavior of the recirculation of burned gas was investigated.
No takes yet. Share an insight, caveat, or question.
Sasaki et al. (2008) studied this question.