Key result
The use of a large-sized Lasso catheter combined with a 3D mapping system significantly reduced atrial fibrillation recurrence at 1 year compared to a standard catheter (18.8% vs. 34.9%, OR 0.489).
Why the study?
Does a large-sized Lasso catheter combined with a 3D mapping system reduce atrial fibrillation recurrence in patients undergoing catheter ablation for symptomatic drug-refractory atrial fibrillation?
Cohort (n=107)
No
Does a large-sized Lasso catheter combined with a 3D mapping system reduce atrial fibrillation recurrence in patients undergoing catheter ablation for symptomatic drug-refractory atrial fibrillation?
Using a large-sized Lasso catheter during AF ablation improves immediate complete antral isolation and reduces 1-year AF recurrence compared to 3D mapping alone.
Hypothesis-generating for large Lasso with 3D mapping in AF ablation; prospective randomized trials needed before practice change.
BACKGROUND AND OBJECTIVES: We aimed to investigate whether a large-sized Lasso catheter could increase the success rate of immediate complete pulmonary vein (PV) antral isolation and improve the outcome of catheter ablation in atrial fibrillation (AF) patients. SUBJECTS AND METHODS: This study included 107 consecutive patients (67 males, mean age: 57.8±9.7 years) who underwent PV mapping and ablation due to symptomatic drug-refractory AF. The first 43 patients underwent isolation of both ipsilateral PVs using the Carto-Merge 3 dimensional mapping system (group 1). The other 64 patients underwent isolation of both ipsilateral PVs using the same technique with a large-sized (a diameter of 30 to 35 mm) Lasso cathe-ter (group 2). When ipsilateral PVs did not show any potential after the initial circumferential ablation, we defined this as 'immediate complete antral isolation (ICAI)'. We compared the AF recurrence rate of both groups. RESULTS: There was no significant difference of the clinical characteristics between group 1 and group 2. All the patients were followed-up for 1 year. The ICAI rate of group 1 and group 2 was significantly different (21% vs. 78%, p<0.001), and the AF recurrence rates of group 1 and group 2 were also different (34.9% vs. 18.8%, p=0.042). Using multiple logistic regression analysis, the use of a large-sized Lasso catheter was a significant predictive factor for preventing recurrence (odds ratio: 0.489, 95% confidence interval: 0.136-0.927). CONCLUSION: It is likely that a large-sized Lasso catheter plays an important role in achieving ICAI and in lowering the rate of AF recurrence.
No takes yet. Share an insight, caveat, or question.
Jang et al. (2011) conducted a cohort in Symptomatic drug-refractory atrial fibrillation (n=107). Large-sized (30-35 mm) Lasso catheter with 3D mapping vs. Standard-sized (25 mm or variable) Lasso catheter with 3D mapping was evaluated on Atrial fibrillation recurrence at 1 year (OR 0.489, 95% CI 0.136-0.927, p=0.042). The use of a large-sized Lasso catheter combined with a 3D mapping system significantly reduced atrial fibrillation recurrence at 1 year compared to a standard catheter (18.8% vs. 34.9%, OR 0.489).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: