Key result
RISE95 cycle ergometry confirms true VO2max in heart failure, outperforming standard RER criteria.
Why the study?
Does a single-visit ramp-incremental step-exercise (RISE95) cycle ergometer test accurately confirm maximal oxygen uptake (VO2max) without relying on secondary respiratory exchange ratio (RER) criteria in male patients with chronic heart failure?
Does a single-visit ramp-incremental step-exercise (RISE95) cycle ergometer test accurately confirm maximal oxygen uptake (VO2max) without relying on secondary respiratory exchange ratio (RER) criteria in male patients with chronic heart failure?
The single-visit RISE95 protocol provides a well-tolerated, robust measure of true VO2max in chronic heart failure patients without relying on the respiratory exchange ratio, which is prone to false-positive results depending on exercise modality and ramp rate.
Cardiopulmonary exercise testing for peak oxygen uptake (VO 2peak ) is widely used to evaluate severity, pathophysiology and prognosis in patients with chronic heart failure (CHF). A VO 2peak ≤14 (or 12 with β-blocker) ml/kg/min is associated with increased mortality and is a key criterion for cardiac transplant listing. A symptom-limited exercise test, however, may elicit a VO 2peak lower than the maximum physiological limit (VO 2max ); the latter commonly “confirmed” using the secondary criterion of respiratory exchange ratio (RER) >1.05. RER, however, is sensitive to the test format. We, therefore, determined if a ramp-incremental (RI) step-exercise (SE) (or RISE) test could determine VO 2max in CHF patients without using RER, by satisfying the criterion that two different work rates are terminated at the same VO 2peak . Twenty-one male CHF patients (NYHA class I: n=3, II: n=16, and III: n=1) initially performed a modified Bruce treadmill test. Patients then completed a symptom-limited RISE95 cycle ergometer test in the format: RI (4–18 W/min; ∼10 min); 5-min recovery (10 W); SE (95% of peak RI work rate). Thirteen of these patients also performed RISE95 tests using slow (RI 3–8 W/min; ∼15 min) and fast (RI 10–30 W/min; ∼6 min) ramp rates. VO 2 and RER were measured breath-by-breath by a mass spectrometer and turbine (MSX, NSpire, UK). Peak VO 2 and RER were compared within-subjects, between RI and SE, by unpaired t test of the final 12 breaths of exercise. This approach allowed VO 2max and its associated 95% confidence limits to be estimated. VO 2peak was similar (p>0.05) in treadmill and cycle exercise (mean±SD: 16.2±2.7 vs 15.0±3.2 ml/kg/min, n=20, respectively), despite RER being greater in cycling (1.08±0.12 vs 1.15±0.09; p<0.05). As a group, VO 2peak was similar (p>0.05) between RI and SE (mean±SD: 14.6±3.2 vs 14.9±3.2 ml/kg/min, n=21). A within-subject comparison, however, revealed that the VO 2max criterion was met in 14 of 21 patients (measurement sensitivity range 0.6–3.8 ml/kg/min), despite RER being >1.05 in the remaining 7 (1.16±0.09). There was no effect of ramp rate on VO 2peak (p>0.05), however RER was greater (p<0.05) in the fast ramp (1.24±0.09) compared to the slow (1.12±0.06). The single-visit RISE95 test incorporating incremental- and step- exercise phases, each to the volitional limit, was well tolerated by CHF patients: The SE phase was contraindicated in only 3 of the 47 tests. The RISE95 detected VO 2max in 14 of 21 patients with a sensitivity of ∼10% (ie, similar to healthy subjects), and without the need for secondary criteria or incidence of false-positive. In contrast, the end-exercise RER was sensitive to both modality and ramp rate and provided a false-positive for VO 2max attainment in every incidence. Therefore, the RISE95 protocol provides a robust measure of VO 2max in CHF patients, to within an individually-defined CI without dependence on secondary criteria.
No takes yet. Share an insight, caveat, or question.
Bowen et al. (2011) studied Chronic heart failure (n=21). Symptom-limited ramp-incremental step-exercise (RISE95) cycle ergometer test vs. End-exercise respiratory exchange ratio (RER >1.05) secondary criterion and modified Bruce treadmill test was evaluated on Confirmation of maximal oxygen uptake (VO2max) by satisfying the criterion that two different work rates (ramp-incremental and step-exercise) are terminated at the same VO2peak (p=>0.05). The RISE95 cycle ergometer protocol confirmed VO2max in 14 of 21 chronic heart failure patients without secondary criteria, whereas RER >1.05 yielded false-positives in the remaining 7 patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: