Simplified procedures for hydrolysis or6 cm) sealed on perpendicularly to the side of the flask about 1 cm below the standard taper joint (Fig. 1).Samples of lipids 0.1 to 100 mg can easily be handled with this size flask.For larger samples, the apparatus may be scaled up proportionately; e.g., a 125 ml flask with a 10-15 ml side tube can be used for samples up toThe flask is designed for use with any pair of immiscible solvents when repeated extraction of the lower phase by the upper phase is desired.An amount of the lower phase just sufficient to fill the side tube (approx.5 ml) is added to the flask, followed hy 5-10 ml of the upper phase.After shaking the mixture and allowing the phases to separate, the flask is slowly tilted to a horizontal position, so that the lower phase runs into the sidc tube, as shown in Fig. 1.At the same time, the upper phase will run out of the flask and is collected in a suitable receiver; removal of all the upper phase is not necessary.After rinsing the mouth of the flask with solvent, the flask is returned to the normal vertical position, more upper phase is added, and the process is repeated at least twice more, or as many times as is found necessary.Quantitative recovery of both the upper and the lower phases is readily achieved by this procedure.5 g.