Answers are grounded in this paper and cite their sources.
Experiments have been conducted to obtain local heat transfer coefficient distributions and average heat transfer associated with impingement of single water jet and a row of circular, free surface-water jets on a constant heat flux surface. The nozzle configuration is reverse cone type, and nozzle exit diameter is 8 mm in the case of single water jet, and nozzle arrays are a row of 3 jets (nozzle dia.=4.6 mm) and a row of 5 jets (nozzle dia.=3.6 mm). Nozzle-to-target plate spacings ranging from 16 mm to 80 mm were investigated for two jet center to center spacings 25 mm and 37.5 mm in the jet velocity of 3 m/s to 8 m/s. For the single jet, the nozzle-to-target plate spacings of maxima in the Nusselt number were observed at r/D≒3 in the jet velocity V0≥6 m/s for H/D from 4 to 10. Except for the condition of V0=8 m/s of H/D=10, the average Nusselt number reveals the following ranking : a row of 5 jets, a row of 3 jets, single jet. Compared with the single jet, average heat transfer enhancement for a row of 3 or 5 jets was presented. Correlations for average heat transfer were presented.
No takes yet. Share an insight, caveat, or question.
Ohm et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: