Evaluates fatigue behavior in notched graphite/epoxy tubes, suggesting effective predictive modeling.
Thin-walled, 2.54-cm diameter tubular specimens of graphite/epoxy (Fiberite T300/1034) were fatigue cycled in combinations of axial, torsion al, and internal pressure loading. Two different four-ply layup configura tions were tested: [0/90] s and [±45] s ; each tube contained a 0.48-cm diameter circular hole penetrating one wall midway along the tube length. S-N curves were developed to characterize fatigue behavior under pure axial, torsional, or internal pressure loading, as well as combined loading fatigue. A theory was developed based a plane stress model which enabled the S-N curve for combined stress states to be predicted from the S-N data for the uniaxial loading modes. Correlation of the theory with the experi mental data proved to be remarkably good.
No takes yet. Share an insight, caveat, or question.
Francis et al. (1977) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: