A method for the determination of pentachlorophenol (PCP) in large volumes of sea water and suspended particulate matter is described. PCP is methylated using methyl iodide in the presence of tetra-butylammonium hydroxide (TBA). The methyl derivative, pentachloroanisole, is quantified by capillary gas chromatography using electron-capture detection. Recovery and the coefficient of variation of the analytical method are found to be: 78% and 4.6% respectively, (n = 17). The PCP is extracted from the sea water by liquid-liquid partition with pentane and sulphuric acid, and by soxhlet extraction with hexane:acetone, 40:60, plus sulphuric acid from the particulate matter. These extraction procedures are also effective for a wide range of other organic contaminants including sterols, chlorinated pesticides and PCBs. The sample clean-up and PCP separation are achieved by liquid-liquid extraction with alkali to isolate the acidic compounds. The PCP is back-extracted into organic solvent after acidifying the aqueous phase and raising the ionic strength. No further clean-up is needed. Following the method validation samples were taken after sewage sludge dumping operations and analysed for PCP in the water and particulate fractions. These results are reported.
No takes yet. Share an insight, caveat, or question.
Rodríguez-Cruz et al. (1992) studied this question.