Why the study?
Does the choice of ablation technology (cryoballoon, laser balloon, contact-force RF) compared to conventional RF affect acute myocardial injury biomarker rise in patients with paroxysmal atrial fibrillation?
Does the choice of ablation technology (cryoballoon, laser balloon, contact-force RF) compared to conventional RF affect acute myocardial injury biomarker rise in patients with paroxysmal atrial fibrillation?
Cryoballoon ablation for atrial fibrillation causes greater acute myocardial injury compared to radiofrequency or laser balloon ablation, though this does not translate to differences in clinical recurrence.
Supports cryoballoon use despite higher biomarkers; challenges direct link between acute injury and AF recurrence.
BACKGROUND: Our study aims to compare acute myocardial injury biomarker rise after atrial fibrillation ablation performed with different technologies. METHODS AND RESULTS: One hundred and ten patients were treated with pulmonary vein isolation with 4 different technologies: open-irrigated tip radiofrequency (RF) catheter in35 patients (Group A), cryoballoon in 35 patients (Group B), visually guided laser balloon in 20 patients (Group C), open-irrigated tip RF catheter with contact-force-sensing technology in 20 patients (Group D). Post-procedure samples of cardiac troponin I (cTnI) and creatinine kinase-MB (CK-MB) were collected at 19 ± 3 h and 43 ± 3 h after ablation. At the first postprocedural sample, cTnI and CK-MB levels were found elevated in all 110 patients with a median value of 2.11 ng/mL and 8.95 ng/mL, respectively. Group B showed cTnI levels increased (median 5.96 ng/mL) compared to other groups (median Group A: 1.72 ng/mL, Group C: 1.54 ng/mL, Group D: 2.0 ng/mL; p < 0.001). Also CK-MB levels resulted higher in cryoablation (median 26.4 ng/mL) compared to other groups (median Group A: 6.40 ng/mL, Group C: 7.15 ng/mL, Group D: 6.50 ng/mL; p < 0.001). No significant association was observed between biomarker levels and recurrences of atrial fibrillation after a mean follow-up of 369 ± 196 days. CONCLUSIONS: Highest markers for myocardial injury were observed in the cryoballoon group. It is possible that a longer delivery energy duration and other factors affecting lesion size resulted in higher amount of cardiac injury in cryoablation. The higher levels of cardiac biomarkers did not translate into a better outcome and its physiologic significance is unknown.
No takes yet. Share an insight, caveat, or question.
Casella et al. (2013) studied this question.