This is the authors' abstract. We don't add key points for this paper.
Influence on an injected current arising from grid voltage is a noticeable issue in the design of grid-tied inverter, especially under low control gain or low power command conditions. The grid voltage full feedforward strategy is a widely used strategy to solve this problem, whereas the physical meanings of the full feedforward items are unclear. In this brief, the full feedforward of the direct current control type LCL-filter inverter and indirect current control type LCCL-filter inverter was reviewed from the circuit and control perspectives. The full feedforward items were rephrased. The new interpretations indicate that the full feedforward strategy is physically rational and complete.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Xiong et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: