Why the study?
What is the incidence and cause of inappropriate ICD interventions in patients with an implantable defibrillator?
Population
214 consecutive patients undergoing implantable defibrillator (ICD) implantation
Design
Cohort
Follow-up
median 2.7 years (3.7 years IQR)
Authors
Loading...
Inappropriate ICD interventions remain frequent in practice; observational data leaves open optimal prevention strategies.
What is the incidence and cause of inappropriate ICD interventions in patients with an implantable defibrillator?
A significant proportion (27%) of ICD patients experience inappropriate interventions, primarily driven by supraventricular arrhythmias, with prior sustained VT being a key risk factor.
Thomas Stüber (2007) studied this question.