Urography was performed in 20 patients using the new non-ionic contrast medium iohexol (Omnipaque) and in 22 patients using the conventional ionic medium metrizoate (Isopaque) in a randomized, double blind comparison. Iohexol caused significantly less subjective reactions and less tachycardia than metrizoate. No significant difference between the contrast media was observed regarding the influence on blood pressure, hematologic parameters, or clinical chemical parameters in blood and urine. Urographic films of similar and high quality were obtained with both contrast media.
No takes yet. Share an insight, caveat, or question.
Levorstad et al. (1983) studied this question.