Why the study?
AngioVac can debulk lead vegetations prior to device removal, offering an alternative to open surgery in high-risk CIED infections.
Does percutaneous debulking of lead vegetations with the AngioVac device prior to CIED removal safely achieve source control without intraprocedural complications or 30-day mortality in patients with systemic CIED endocarditis?
Does percutaneous debulking of lead vegetations with the AngioVac device prior to CIED removal safely achieve source control without intraprocedural complications or 30-day mortality in patients with systemic CIED endocarditis?
Answers are grounded in this paper and cite their sources.
This 5-patient case series demonstrates that percutaneous debulking of large CIED lead vegetations using the AngioVac system prior to transvenous lead extraction can be performed safely without intraprocedural complications or 30-day mortality in patients at high or prohibitive surgical risk.
Background Systemic infection of cardiac implantable electronic devices (CIEDs) usually manifests as endocarditis, with vegetations involving the lead and cardiac valves. Cardiac implantable electronic device systemic infections involve the transvenous or epicardial portion of the lead in addition to adjacent endocardium. History, blood cultures, and imaging are the cornerstone of diagnosis. The treatment of CIED infections involves intravenous antibiotics, complete removal of the CIED, and reimplantation after clearance of bacteraemia. AngioVac is used for the removal of right atrial masses, right atrial thrombi, and right-sided endocarditis vegetations. It can provide a mechanism for debulking of lead vegetations prior to their removal. Case summary We describe a case series of five patients who underwent debulking of lead vegetations with AngioVac prior to cardiac implantable electronic device removal. Four of our patients had defibrillators implanted for ventricular tachycardia. Three patients had involvement of the right atrial lead. Staphylococcus aureus was the most common organism involved. All patients had successful debulking of lead vegetations without any intraprocedural complications or 30-day mortality. Discussion Traditionally, large vegetations (>2 cm) involving the CIED apparatus required open surgery before device removal but more recently, AngioVac device has been used for the removal of vegetations from intracardiac leads before their removal, offering an alternative to the traditional surgical approach for high or prohibitive risk patients. Our case series adds to the growing body of evidence supporting the use of AngioVac in debulking leads prior to their removal.
No takes yet. Share an insight, caveat, or question.
Haider et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: