The reaction between soluble Mn(IV) and tamoxifen can produce chemiluminescence and formaldehyde can enhance this chemiluminescence reaction. A tamoxifen molecular imprinted polymer (MIP) was synthesized and its adsorption selectivity to tamoxifen in aqueous solution was evaluated. Using a synthesized tamoxifen MIP as the recognition material and a soluble Mn(IV)-formaldehyde-tamoxifen chemiluminesence system as the detection system, a new molecule imprinting-chemiluminesence method of determination of tamoxifen was established. The response range of this method was 1.0 x 10(-7)-6.0 x 10(-6) g/mL, with a linear correlation coefficient of 0.997. The detection limit was 4 x 10(-8) g/mL. The relative standard deviation for 5.0 x 10(-7) g/mL tamoxifen solution was 4.1% (n = 9).