Why the study?
Flow-mediated dilation testing requires skilled ultrasonography in a hospital setting, creating a need for convenient methods to assess peripheral arterial elasticity and functional reactivity.
Does a smartphone-based volume-oscillometry device detect changes in peripheral arterial elasticity following reactive hyperemia in normal volunteers?
Does a smartphone-based volume-oscillometry device detect changes in peripheral arterial elasticity following reactive hyperemia in normal volunteers?
A novel smartphone-based volume-oscillometry device can detect expected changes in peripheral arterial elasticity during reactive hyperemia, suggesting potential as a convenient alternative to traditional FMD testing.
Answers are grounded in this paper and cite their sources.
May enable home-based endothelial assessment; leaves open validation against standard FMD before any clinical use.
The flow-mediated dilation (FMD) test is commonly utilized and is the only technique for the assessment of vascular endothelial cell function. With this test, the augmentation of a brachial artery diameter following reactive hyperemia is measured precisely using ultrasonography by a skilled operator. This is a hospital-only test, and would be more useful if conveniently performed at home. This paper describes a first approach for studying the impact of changes in peripheral arterial elasticity, with prospects towards possible assessment of functional reactivity. A recently developed smartphone-based instrument was used to measure elastic properties of finger and radial arteries, related to stiffness and vasodilatation, as a function of distending pressure derived by photo-plethysmographic volume-oscillometry. Elasticity changes in both arteries before and after a 5-min supra-systolic upper-arm cuff occlusion were successfully obtained in 15 normal volunteers. The index-values of stiffness and vasodilatation showed, respectively, a significant decrease and increase ( p < 0.01), demonstrating clearly the expected elasticity changes with hyperemia, which could be consistent with the clinically-stated reaction in an FMD test. The results suggest that this method could easily provide important information of both elasticity and vasodilatation. It appears promising as a convenient assessment method to contribute to arteriosclerotic cardiovascular screening.