Why the study?
Does mitral valve annuloplasty improve mitral valve structural parameters and annulus systolic function as evaluated by RT-3D TEE in patients with mitral valve prolapse?
Does mitral valve annuloplasty improve mitral valve structural parameters and annulus systolic function as evaluated by RT-3D TEE in patients with mitral valve prolapse?
RT-3D TEE can quantitatively demonstrate significant improvements in mitral valve structure and annulus systolic function following mitral valve annuloplasty for prolapse.
RT-3D TEE quantifies mitral annular changes post-annuloplasty; leaves open whether it alters surgical decisions or outcomes.
Objective To quantitatively evaluate the variation of preoperative and postoperative structure and function of mitral valve after mitral valve annuloplasty(MVP) for mitral valve prolapse by real-time three-dimensional transesophageal echocardiography(RT-3D TEE). Methods Thirty patients with mitral valve prolapse for MVP were studied, the minimum area of the three-dimensional view of the annulus(A3Dmin), three dimensional circumference(C3D), anterolateal-to-posteromedial diameter(DAlPm), anterior-to-posteior diameter(DAP), height (H), the ratio of annulus height to anterolated-to-posteromedial diameter(H/DAlPm), aorto-mitral angle(θ), the ellipticity of the the anterior-to-posterior diameter and anterolateal-to-posteromedial diameter of the annulus(E2D), the three-dimensional exposed area of the leaflet(A3DE), prolapse height(HProl), prolapse volume(VProl), non-planarity angle(θNPA) were evaluated by RT-3D TEE before and after operation. Coaptation area(CoapA), coaptation index(CPI), annulus systolic function index were calculated. Results Compared with the preoperation, A3Dmin, C3D, DAlPm, DAP, H, H/DAlPm, A3DE, HProl, VProl, θNPA of postoperative were reduced, E2D, CoapA, CPI, annulus systolic function index of the postoperation increased, the difference of above parameters were statistically significant (P<0.05). CPI and annulus systolic function index were negatively correlated with the area of valve regurgitation area before and aftere operation (r=-0.79, P<0.01; r=-0.67, P<0.01). Furthermore, CPI was closely correlated with annulus systolic function index (r=0.63, P<0.01). Conclusions After MPV, mitral valve three-dimensional structural parameters are significantly changed, CPI and annulus systolic function are improved. CPI is closely correlated with annulus systolic function, and RT-3D TEE can quantitatively evaluate the structure and function of mitral valve before and after MPV.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: