Key result
Automated 3D TEE distinguishes mitral valve prolapse by altering ~79% of apparatus morphofunctional parameters.
Why the study?
There is limited information on automatic mitral valve apparatus analysis using 3D TEE software in patients with mitral valve prolapse compared to those without structural cardiac chamber remodeling.
Does automated 3D transesophageal echocardiography software identify structural differences in the mitral valve apparatus between patients with mitral valve prolapse and those without structural remodeling?
Cohort (n=102)
No
Does automated 3D transesophageal echocardiography software identify structural differences in the mitral valve apparatus between patients with mitral valve prolapse and those without structural remodeling?
Automated 3D TEE software can reliably identify distinct morphofunctional changes in the mitral valve apparatus in patients with mitral valve prolapse, potentially aiding in surgical planning.
Answers are grounded in this paper and cite their sources.
May support automated mitral assessment in prolapse; leaves open impact on surgical planning or outcomes.
Background: There is a paucity of information concerning automatic mitral valve apparatus (MVA) analysis of patients with mitral valve prolapse (MVP). We aimed to study with an automatic three-dimensional (3D) transesophageal echocardiography (TEE)-dedicated software, patients with moderate and severe mitral regurgitation when compared to patients with no structural cardiac chamber alterations [patients with patent foramen ovale (PFO) who underwent TEE]. Methods: We employed TEE software dedicated to automatic analysis of 34 parameters of the MVA, comparing MVP patients with moderate and severe mitral regurgitation and patients with PFO without cardiac chamber structural alterations. Mitral valve effective regurgitant orifice (ERO) and regurgitant volume were correlated to automatic MVP parameters. Results: Fifty-nine MVP patients and 43 PFO patients were analyzed. All MVP patients presented P2 MVP, 15 (25.4%) with both posterior and anterior prolapse. Twenty-seven automatic parameters (79%) were different concerning MVP and PFO patients (P<0.05): diameters, area, perimeter, height, angle, coaptation width, length, closure line length, and annulus. ERO was 0.43±0.11 cm2, and regurgitant volume was 62.2±14.9 mL/beat. Automatic analysis correlated to 75th percentile ERO MVP patients (ERO >0.48 cm2): posterior leaflet area (r=0.74, P=0.03); posterior leaflet length (r=0.73, P=0.03); tenting area (r=0.41, P=0.048). Conclusions: Automatic mitral valve parameters differed significantly between patients with MVP and those without structural cardiac chamber remodeling. In exploratory analysis, patients in the upper range of ERO values (≥75th percentile) showed patterns involving posterior leaflet geometry that were consistent with the associations observed in continuous-variable analysis. These findings support the potential role of automated 3D assessment in the anatomical characterization of MVP.
No takes yet. Share an insight, caveat, or question.
Vieira et al. (2026) conducted a cohort in Mitral valve prolapse with moderate to severe mitral regurgitation (n=102). Mitral valve prolapse (moderate to severe mitral regurgitation) vs. Patent foramen ovale without structural cardiac chamber alterations was evaluated on Differences in 34 automatic morphofunctional parameters of the mitral valve apparatus evaluated by 3D TEE (p=<0.05). Automated 3D transesophageal echocardiography parameters of the mitral valve apparatus differed significantly (27 out of 34 parameters) between patients with mitral valve prolapse and those without structural cardiac chamber remodeling.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: