Why the study?
The impact of individual transcatheter heart valve sizing for patients with borderline aortic annulus anatomy undergoing TAVI remains unclear.
Does suboptimal transcatheter heart valve sizing increase the risk of adverse clinical outcomes in patients undergoing TAVI?
Does suboptimal transcatheter heart valve sizing increase the risk of adverse clinical outcomes in patients undergoing TAVI?
Suboptimal TAVI prosthesis sizing, particularly undersizing, is associated with an increased risk of all-cause death and unplanned repeat intervention at 1 year.
Suboptimal THV sizing was associated with higher mortality and reintervention; leaves open optimal strategy for borderline annuli.
Objectives To investigate the impact of transcatheter heart valve (THV) sizing on procedural results and clinical outcomes following transcatheter aortic valve implantation (TAVI). Background The impact of individual THV sizing for patients with borderline aortic annulus anatomy remains unclear. Methods In the prospective BernTAVI registry, THV sizing conditions were retrospectively evaluated, and patients were categorized into three groups based on the recommendations and the sizing chart of the manufacturers: optimal sizing, borderline sizing (THV size located within 5% to each border of the optimal sizing recommendation), and suboptimal sizing (THV size outside the recommended range). The latter two groups were further subcategorized into THV‐oversizing and THV‐undersizing. The primary endpoint was a composite of all‐cause death and unplanned repeat intervention at 1 year. Results Out of a total of 1,638 patients who underwent TAVI, 9.5 and 15.6% of patients were categorized into the borderline and suboptimal sizing group, respectively. Device success was achieved in 87.4, 88.9, and 83.6% of patients with optimal, borderline, and suboptimal sizing, respectively. The primary endpoint occurred in 12.3% of patients with optimal sizing, 14.9% of patients with borderline sizing (HR adj 1.35, 95%CI 0.87–2.09), and in 17.4% of patients with suboptimal sizing (HR adj 1.42, 95%CI 1.01–1.99). Within the suboptimal sizing cohort, unfavorable outcomes were mainly associated with THV undersizing (device success: 76.4%, primary endpoint: 23.9%, HR adj 1.98, 95%CI 1.36–2.87). Conclusion Suboptimal TAVI prosthesis sizing is associated with an increased risk of all‐cause death and unplanned repeat intervention within 1 year largely attributable to undersized THV prostheses.
No takes yet. Share an insight, caveat, or question.
Okuno et al. (2021) studied this question.