Why the study?
Hypoattenuating leaflet thickening is commonly identified after TAVR and linked to stroke and structural valve deterioration, but routine anticoagulation is controversial. The authors aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT.
Does valve oversizing by more than 20% increase the risk of hypoattenuating leaflet thickening (HALT) in patients undergoing TAVR with SAPIEN 3 valves?
Does valve oversizing by more than 20% increase the risk of hypoattenuating leaflet thickening (HALT) in patients undergoing TAVR with SAPIEN 3 valves?
Valve oversizing by more than 20% during TAVR with SAPIEN 3 valves is strongly associated with an increased risk of hypoattenuating leaflet thickening (HALT).
BACKGROUND: Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT. METHODS: We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team. RESULTS: (p = .032), but received comparable size valves. In multivariate regression, valve oversizing by more than 20% was associated with increased risk of HALT, OR 23.5, 95% CI 2.5-223, (p = .006). After initiation of anticoagulation, patients with HALT had similar rates of stroke, major bleeding, and all-cause mortality out to an average of 243 days. CONCLUSIONS: In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials.
No takes yet. Share an insight, caveat, or question.
Simpson et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: