Key result
Non-insulin-assisted minimal model correlates well with standard 2-day clamp protocols for metabolic assessment.
Answers are grounded in this paper and cite their sources.
Demonstrates concordance between minimal model and clamp estimates of glucose effectiveness and insulin sensitivity in normoglycaemic adults, indicating the non-insulin-assisted IVGTT is reliable.
BACKGROUND: We investigated the concordance between glucose effectiveness (SG) and insulin sensitivity (SI), derived from the unmodified dynamic non-insulin-assisted intravenous glucose tolerance test (IVGTT) implemented by SG(MM) and SI(MM); simulation analysis and modelling/conversational interaction (SAAM/CONSAM) versus the eu/hyperglycaemic basal insulinaemic and the euglycaemic hyperinsulinaemic clamp (SG(CLAMP) and SI(CLAMP)). METHODS: Twenty-seven of 30 normoglycaemic subjects completed a (1) euglycaemic hyperinsulinaemic clamp, (2) 6-h eu/hyperglycaemic near-normoinsulinaemic pancreatic clamp with hyperglycaemia present over the final 2 h of the clamp (Day 2 study), (3) identical clamp to (2) but with euglycaemia maintained over the entire 6 h (Day 3 study) and (4) IVGTT. SG(CLAMP) was calculated in two ways based on data from study (2) alone (Day 2 SG(CLAMP210-240')) or from data from study day (2) and (3) (Day 2-3 SG(CLAMP330-360')). RESULTS: SG(MM) was unrelated to the magnitude of endogenous insulin release (AIR). The single-day (Day 2) and two-day (Day 2 and 3) SG(CLAMP) protocols correlated (r = 0.72, p = 0.003), but SG(CLAMP210-240') was significantly (p = 0.001) higher than SG(CLAMP330-360'). Employing the Day 2 and 3 SG(CLAMP) protocol, the whole body SG(CLAMP330-360') was similar to SG(MM) (1.80 ± 0.82 versus 1.73 ± 0.58 dL/min) and correlated (r = 0.45, p < 0.02). SG(CLAMP210-240') did not correlate with SG(MM) (r = 0.24). SI(MM) and SI(CLAMP) were similar (0.093 ± 0.060 versus 0.087 ± 0.029 dL/min per mU/L) and correlated (r = 0.76, p < 0.001). CONCLUSIONS: The time-dependent increase in glucose disposal observed during a prolonged 6-h clamp significantly influences the estimation of SG(CLAMP), and significant concordance coefficients are observed between SG(MM), and SG(CLAMP330-360'), and SI(MM) and SI(CLAMP).
No takes yet. Share an insight, caveat, or question.
Henriksen et al. (2010) studied Normoglycaemia (n=30). Non-insulin-assisted minimal model (IVGTT) vs. Eu/hyperglycaemic basal insulinaemic and euglycaemic hyperinsulinaemic clamp was evaluated on Concordance of glucose effectiveness (SG) and insulin sensitivity (SI) between minimal model and clamp techniques (r = 0.45 for SG; r = 0.76 for SI, p=<0.02). Non-insulin-assisted minimal model measurements were concordant with 2-day clamp protocols for both glucose effectiveness and insulin sensitivity.
Synapse has enriched 10 related papers. Consider them for comparative context: