Why the study?
Does real time 3D-TEE improve diagnostic utility compared to 2D echocardiography in a patient with mitral flexible annuloplasty band displacement?
Does real time 3D-TEE improve diagnostic utility compared to 2D echocardiography in a patient with mitral flexible annuloplasty band displacement?
Real time 3D-TEE is an effective tool for evaluating mitral annuloplasty band displacement and planning appropriate surgical intervention.
Answers are grounded in this paper and cite their sources.
May aid surgical planning in complex mitral band detachment; hypothesis-generating for routine 3D-TEE use.
Mini‐Abstract We describe a patient with mitral flexible annuloplasty band displacement. The diagnosis was made performing a comprehensive echocardiographic assessment. Compared with two‐dimensional echocardiography, real time three‐dimensional transesophageal echocardiography (3 D ‐ TEE ) provided additional information and diagnostic utility, allowing an accurate evaluation of the underlying pathology. Using 3 D ‐ TEE , we were able to exactly define the site, size, and shape of the detachment and to detect the precise anatomical relation existing between the displaced band and the surrounding cardiac structures. Therefore, real time 3 D ‐ TEE can be considered of great assistance to the cardiac surgeon, being an effective tool in planning appropriate intervention.
No takes yet. Share an insight, caveat, or question.
Scandura et al. (2012) studied this question.