Why the study?
The study aimed to compare mortality rates, re-intervention rates, and volumetric changes in the true and false lumens of the aorta following conventional hemi-arch repair versus frozen elephant trunk techniques.
Does the frozen elephant trunk technique improve aortic volumetric changes and reduce re-interventions compared to conventional hemi-arch repair in patients with acute type A aortic dissection?
Does the frozen elephant trunk technique improve aortic volumetric changes and reduce re-interventions compared to conventional hemi-arch repair in patients with acute type A aortic dissection?
The frozen elephant trunk technique promotes favorable aortic remodeling with true lumen expansion and stable false lumen volume, reducing the need for re-intervention compared to conventional hemi-arch repair in acute type A aortic dissection.
Answers are grounded in this paper and cite their sources.
FET may promote true lumen expansion; leaves open whether it reduces mortality or reinterventions in acute type A dissection.
The aim of this study was to compare the mortality rates, re-intervention rates, and volumetric changes in aortas following surgery, in terms of the true lumen and false lumen changes, using conventional hemi-arch repair (CET) and frozen elephant trunk (FET) techniques. During the period from 2015 to 2018, 66 patients underwent surgical treatment for acute aortic dissection (Debakey type 1). Demographic and procedure-related data were evaluated. We measured volumetric change before surgical treatment, at discharge, and at 12- and 24-month time points based on computed tomography angiography. The study cohort was divided into two groups (FET vs. CET). The mean age of the patients was 56.9 ± 9.4 years in the FET group versus 63.6 ± 11 years in the CET group (p = 0.063). The mean follow-up time was 24 ± 6 and 25 ± 5 months for the FET and CET groups, respectively. There were no significant differences between the two groups in terms of the medical histories of the cohorts. The results showed a significant increase in true lumen volume after the FET procedure (within 24 months postoperatively; p = 0.005), and no significant changes in total (p = 0.392) or false lumen (p = 0.659) volumes were noted. After the CET procedure, there were significant increases in total and false lumen volumes (p = 0.013, p = 0.042), while no significant change in true lumen was observed (p = 0.219). The volume increase in true lumen after the FET procedure was higher compared to the CET group at all postoperative time points (at discharge, 12 months, and 24 months) without significant evidence (p = 0.416, p = 0.422, p = 0.268). At two years, the volume increase in false lumen was significantly higher among the CET group compared to the FET group (p = 0.02). The Kaplan–Meier curve analysis showed that patients who underwent the CET procedure underwent significantly more re-interventions due to false lumen expansion of the descending aorta (p = 0.047). Present study results indicate that the true and false lumen changes in the aorta following the FET and CET procedures were different. FET led to a significant increase in true lumen volume, while false lumen volume remained stable; however, after the CET procedure, significant false lumen enlargement was noted at mid-term follow-up time points. The re-intervention rate after CET was higher due to false lumen expansion.
No takes yet. Share an insight, caveat, or question.
Ibrahim et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: