Why the study?
Does mechanical esophageal displacement by TEE transducer reduce esophageal luminal temperature rise during radiofrequency catheter ablation in patients with atrial fibrillation?
Does mechanical esophageal displacement by TEE transducer reduce esophageal luminal temperature rise during radiofrequency catheter ablation in patients with atrial fibrillation?
Mechanical esophageal displacement using a TEE transducer during AF ablation significantly reduces esophageal temperature rise, offering a practical method to potentially lower the risk of atrioesophageal fistula.
Answers are grounded in this paper and cite their sources.
Esophageal displacement may limit temperature rise during AF ablation; leaves open whether it reduces fistula risk in prospective trials.
INTRODUCTION: Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality. OBJECTIVE: This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibrillation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. METHODS: Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8 ± 14 [17-84] years old), with mean EF of 0.66 ± 0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmonary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiography transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. RESULTS: The mean esophageal displacement was 4 to 9.1cm (5.9 ± 0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40ºC/irrigated catheter or 50W/60ºC/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11 ± 0.13ºC versus 1.1 ± 0.4ºC respectively, P<0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echocardiography transducer insertion were observed. CONCLUSION: Mechanical esophageal displacement by transesophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was sufficient to allow safe radiofrequency application without esophagus overlapping, being a convenient alternative in reducing the risk of atrioesophageal fistula.
No takes yet. Share an insight, caveat, or question.
Mateos et al. (2015) studied this question.